Compensate Chokes Vertical2023-05-06T20:13:55+00:00

Compensate Chokes Vertical

  • CCSP CASE TYPE 10 CCSP-6210-0102 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • Out of Stock
    CCSP CASE TYPE 10 CCSP-6210-02D5 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • Out of Stock
    CCSP CASE TYPE 10 CCSP-6210-D504 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • CCSP CASE TYPE 14 CCSP-6214-0104 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • CCSP CASE TYPE 14 CCSP-6214-0201 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • Out of Stock
    CCSP CASE TYPE 14 CCSP-6214-D610 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • CCSP CASE TYPE 20 CCSP-C220-0107 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • Out of Stock
    CCSP CASE TYPE 20 CCSP-C220-0204 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • Out of Stock
    CCSP CASE TYPE 20 CCSP-C220-D327 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • CCSP CASE TYPE 22 CCSP-6222-0122 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • Out of Stock
    CCSP CASE TYPE 22 CCSP-6222-0206 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • Out of Stock
    CCSP CASE TYPE 22 CCSP-6222-0402 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • CCSP CASE TYPE 33 CCSP-6233-0133 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • CCSP CASE TYPE 33 CCSP-6233-0207 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0
  • CCSP CASE TYPE 33 CCSP-6233-0602 Compensated Choke SMD and custom versions on request
    Nominal currant: 0,5 ÷ 4A Nominal inductance: 0,5 ÷ 39mH Max operating voltage: UR (see table) Test voltage: 1,8 kV AC / 2s, wdg. to wdg. 2kV AC / 2s, wdg. to ambient Operating frequency: DC to 400 Hz Climatic class: 25/100/21 as per IEC 60068-1 Infiammability: UL 94 V-0

Title

Go to Top